Difference between revisions of "Oxygen Tank"

From Space Engineers Wiki
Jump to: navigation, search
(re-arranged some things, added headers and some wording. Otherwise this is also great)
m (Overview: Added oxygen time)
 
(20 intermediate revisions by 8 users not shown)
Line 1: Line 1:
{{itembox
+
{{SimpleItembox|Mod:Vanilla/CubeBlock/OxygenTank
| item = Oxygen Tank
+
|Size||Mass||Integrity||BuildTimeSeconds||ResourceSinkGroup||InventoryVolume|L|BlueprintClasses||GasCapacity|L|OperationalPowerConsumption|W|StandbyPowerConsumption|W|IsAirTight||PCU}}
| description = A functional block for storing and distributing breathable [[Oxygen]] in a compressed state.
+
{{SimpleItembox|Mod:Vanilla/CubeBlock/OxygenTankSmall
| tool = no
+
|Size||Mass||Integrity||BuildTimeSeconds||ResourceSinkGroup||InventoryVolume|L|BlueprintClasses||GasCapacity|L|OperationalPowerConsumption|W|StandbyPowerConsumption|W|IsAirTight||PCU}}
| largeship = yes
+
{{CategorizeComponents|Mod:Vanilla/CubeBlock/OxygenTank}}
| smallship = yes
+
== Overview ==
| component = no
+
The Oxygen Tank is a functional Block used to store and distribute breathable [[Oxygen]] either through [[Conveyor]]s or inside [[Oxygen Bottle]]s.
| rawmaterial = no
 
| material = no
 
  
| sbuildtime = 13
+
A filled '''large tank''' holds ''{{timespan|{{#expr: {{#show:Mod:Vanilla/CubeBlock/OxygenTank|?GasCapacity#-n}}/0.063}}}}'' worth of oxygen '''for one player,''' while the '''small tank''' holds ''{{timespan|{{#expr: {{#show:Mod:Vanilla/CubeBlock/OxygenTankSmall|?GasCapacity#-n}}/0.063}}}}'' worth. For more figures about players O2 consumption, see [[Oxygen]].
| spowerconsumption = 0.001
 
| spowerstandby = 0.0
 
 
 
| scomponentstructure = 2
 
| scomponent1 = Steel Plate
 
| scomponent1amt = 10
 
| scomponent2 = Computer
 
| scomponent2amt = 3
 
| scomponent3 = Large Steel Tube
 
| scomponent3amt = 2
 
| scomponent4 = Small Steel Tube
 
| scomponent4amt = 10
 
| scomponent5 = Construction Component
 
| scomponent5amt = 10
 
| scomponent6 = Steel Plate
 
| scomponent6amt = 4
 
 
 
| swidth = 3
 
| sheight = 3
 
| sdepth = 3
 
 
 
| lbuildtime = 45
 
| lpowerconsumption = 0.001
 
| lpowerstandby = 0.0
 
 
 
| lcomponentstructure = 2
 
| lcomponent1 = Steel Plate
 
| lcomponent1amt = 20
 
| lcomponent2 = Construction Component
 
| lcomponent2amt = 40
 
| lcomponent3 = Computer
 
| lcomponent3amt = 8
 
| lcomponent4 = Small Steel Tube
 
| lcomponent4amt = 60
 
| lcomponent5 = Large Steel Tube
 
| lcomponent5amt = 40
 
| lcomponent6 = Steel Plate
 
| lcomponent6amt = 60
 
 
 
| lwidth = 1
 
| lheight = 2
 
| ldepth = 1
 
 
 
| version = 01.078.009
 
}}
 
 
 
== Overview ==
 
>
 
The Oxygen Tank is a functional Block available for Small Ships, Large Ships and Stations.<br /> It is used to store and distribute breathable [[Oxygen]] either through [[Conveyor]]s or inside [[Oxygen Bottle]]s.
 
  
 
== Usage ==
 
== Usage ==
Line 67: Line 16:
 
If a room should be depressurized by an air vent, there must be oxygen tanks present in the conveyor network that have still enough free storage space to hold the pumped down oxygen in compressed state. Otherwise a room cannot be depressurized using [[Air Vent]]s.
 
If a room should be depressurized by an air vent, there must be oxygen tanks present in the conveyor network that have still enough free storage space to hold the pumped down oxygen in compressed state. Otherwise a room cannot be depressurized using [[Air Vent]]s.
  
== Indicator ==
+
=== Indicator ===
 
The colored indicators on the tank show at a glance the current oxygen level inside the tank.
 
The colored indicators on the tank show at a glance the current oxygen level inside the tank.
  
Line 73: Line 22:
 
{| class="wikitable"
 
{| class="wikitable"
 
|-
 
|-
|[[File:Air_Vent_Front_Indicator_Green.png]] [[File:Air_Vent_Front_Indicator_Green.png]] [[File:Air_Vent_Front_Indicator_Green.png]] [[File:Air_Vent_Front_Indicator_Green.png]]||Oxygen Tank is not stockpiling and can be drained.<br />'''0:''' O2 level < 25%, '''1:''' 25% <= O2 level < 50%, '''2:''' 50% <= O2 level < 75%, '''3:''' O2 level > 75%, '''4:''' Tank full.
+
| style="width: 140px;"|[[File:Air_Vent_Front_Indicator_Green.png]] [[File:Air_Vent_Front_Indicator_Green.png]] [[File:Air_Vent_Front_Indicator_Green.png]] [[File:Air_Vent_Front_Indicator_Green.png]]||Oxygen Tank is not stockpiling and can be drained.<br />
 +
'''0:''' O2 level < 25%<br />
 +
'''1:''' 25% <= O2 level < 50%<br />
 +
'''2:''' 50% <= O2 level < 75%<br />
 +
'''3:''' O2 level > 75%<br />
 +
'''4:''' Tank full.
 
|-
 
|-
|[[File:Air_Vent_Front_Indicator_Blue.png]] [[File:Air_Vent_Front_Indicator_Blue.png]] [[File:Air_Vent_Front_Indicator_Blue.png]] [[File:Air_Vent_Front_Indicator_Blue.png]]||Oxygen Tank is set to Stockpile. The tank will not release any oxygen and will drain other tanks that are not stockpiling.<br />'''0:''' O2 level < 25%, '''1:''' 25% <= O2 level < 50%, '''2:''' 50% <= O2 level < 75%, '''3:''' O2 level > 75%, '''4:''' Tank full.
+
|[[File:Air_Vent_Front_Indicator_Blue.png]] [[File:Air_Vent_Front_Indicator_Blue.png]] [[File:Air_Vent_Front_Indicator_Blue.png]] [[File:Air_Vent_Front_Indicator_Blue.png]]||Oxygen Tank is set to Stockpile. The tank will not release any oxygen and will drain other tanks that are not stockpiling.<br />
 +
'''0:''' O2 level < 25%<br />
 +
'''1:''' 25% <= O2 level < 50%<br />
 +
'''2:''' 50% <= O2 level < 75%<br />
 +
'''3:''' O2 level > 75%<br />
 +
'''4:''' Tank full.
 
|-
 
|-
 
|[[File:Air_Vent_Front_Indicator_Red.png]] [[File:Air_Vent_Front_Indicator_Red.png]] [[File:Air_Vent_Front_Indicator_Red.png]] [[File:Air_Vent_Front_Indicator_Red.png]]||Oxygen Tank deactivated or unpowered.
 
|[[File:Air_Vent_Front_Indicator_Red.png]] [[File:Air_Vent_Front_Indicator_Red.png]] [[File:Air_Vent_Front_Indicator_Red.png]] [[File:Air_Vent_Front_Indicator_Red.png]]||Oxygen Tank deactivated or unpowered.
|}
 
 
 
== Capacities ==
 
Game version: 1.078.009
 
{| class="wikitable"
 
|-
 
|'''Large grid oxygen tank'''||100,000 O2
 
|-
 
|'''Small grid oxygen tank'''||50,000 O2
 
 
|}
 
|}
  
 
== Media ==
 
== Media ==
 +
<gallery>
 +
File:Oxygen_Tank_OxyTank01.jpg|Old tank model
 +
File:Oxygen_Tank_UI.png|Tank terminal UI
 +
</gallery>
  
 
== Tips ==
 
== Tips ==
* If your oxygen tank is full, and you have no where else to vent it. You can eject oxygen directly out using [[Connector]]s.
+
* It's helpful to keep one oxygen tank have its conveyor set to off, so that you can have one always ready. Just be sure to turn off your [[Oxygen Generator]] when you flip it back on.
* It's helpful to keep one oxygen tank have it's conveyor set to off, so that you can have one always ready. Just be sure to turn off your [[Oxygen Generator]] when you flip it back on.
 
  
 
== Known Issues ==
 
== Known Issues ==
Line 113: Line 65:
 
  '''Interface name:''' IMyOxygenTank
 
  '''Interface name:''' IMyOxygenTank
  
This block was introduced in V1.074.<br /
+
== Update History ==
 +
<div style="-webkit-border-image: none;-webkit-box-shadow: rgba(0, 0, 0, 0.046875) 0px 1px 1px 0px inset;background-color: #eeeeee;border-bottom-color: #AFAFAF;border-bottom-left-radius: 3px;border-bottom-right-radius: 3px;border-bottom-style: solid;border-bottom-width: 1px;border-left-color: #AFAFAF;border-left-style: solid;border-left-width: 1px;border-right-color: #AFAFAF;border-right-style: solid;border-right-width: 1px;border-top-color: #AFAFAF;border-top-left-radius: 3px;border-top-right-radius: 3px;border-top-style: solid;border-top-width: 1px;box-shadow: rgba(0, 0, 0, 0.046875) 0px 1px 1px 0px inset;color: #333;display: block;font-family: 'Helvetica Neue', Helvetica, Arial, sans-serif;font-size: 1em;height: auto;line-height: 20px;margin-bottom: 5px;margin-left: 8px;margin-right: 8px;margin-top: 0px;min-height: 20px;padding-bottom: 4px;padding-left: 4px;padding-right: 4px;padding-top: 4px;width: auto;">
 +
{| class="wikitable" style="width: 100%"
 +
|style="text-align: left;width: 8%"| [[Update 01.074]] ||style="padding-left: 10px;padding-right: 10px;"|
 +
*Oxygen Tank block introduced
 +
|}
 +
 
 +
</div>
 +
 
 +
[[Category:Oxygen Blocks]]
 +
[[Category:Functional Blocks]]

Latest revision as of 20:53, 9 February 2021

Oxygen Tank Icon.png
Large Ship / Station
Oxygen Tank
Large Ship Icon.png

ComponentsRequired

 Functional 

 Hack 

Dimensions (W,H,L)1,2,1
Mass3,161.6 kg
3,161,600 g
3,161,600,000 mg
3.162 t
Integrity12,508
Build time32 s
Power Consumer GroupFactory
Inventory Volume4,000 L
4 m³
400 hL
Accepts Item TypesOxygen Bottles
Gas Capacity100,000 L
10,000 hL
100 m³
Power Consumption1,000 W
1 kW
1.0e-3 MW
Idle Power Consumption1 W
1.0e-3 kW
1.0e-6 MW
Is AirtightNo
PCU Cost25
BrowseLast edit: 2020-04-05
Oxygen Tank Small Icon.png
Small Ship
Oxygen Tank
Small Ship Icon.png

ComponentsRequired

 Functional 

 Hack 

Dimensions (W,H,L)3,3,3
Mass641.6 kg
641,600 g
641,600,000 mg
0.642 t
Integrity2,538
Build time14 s
Power Consumer GroupFactory
Inventory Volume4,000 L
4 m³
400 hL
Accepts Item TypesOxygen Bottles
Gas Capacity50,000 L
5,000 hL
50 m³
Power Consumption1,000 W
1 kW
1.0e-3 MW
Idle Power Consumption1 W
1.0e-3 kW
1.0e-6 MW
Is AirtightPartially
PCU Cost25
BrowseLast edit: 2020-04-24

Overview

The Oxygen Tank is a functional Block used to store and distribute breathable Oxygen either through Conveyors or inside Oxygen Bottles.

A filled large tank holds 18 days, 8 hours, 55 minutes and 1 second worth of oxygen for one player, while the small tank holds 9 days, 4 hours, 27 minutes and 30 seconds worth. For more figures about players O2 consumption, see Oxygen.

Usage

If connected to a Conveyor Network via one of the inventory access points, the oxygen tank can automatically pull in oxygen from attached oxygen sources (like other oxygen tanks, Oxygen Generators, Oxygen Farms) to store and provide oxygen to Air Vents or other oxygen tanks in the network.

If set to "Stockpile" in the control panel, an oxygen tank will store oxygen that gets provided to it through the conveyor network, but will not deliver it back into the network when requested by other blocks. (for example by an air vent). An oxygen tank can be used to refill Oxygen Bottles by placing empty or partly filled O2 bottles into the O2 tanks inventory and either clicking "Refill bottles" or activating the control panel option "Auto-Refill".

If a room should be depressurized by an air vent, there must be oxygen tanks present in the conveyor network that have still enough free storage space to hold the pumped down oxygen in compressed state. Otherwise a room cannot be depressurized using Air Vents.

Indicator

The colored indicators on the tank show at a glance the current oxygen level inside the tank.

Game version: 1.107

Air Vent Front Indicator Green.png Air Vent Front Indicator Green.png Air Vent Front Indicator Green.png Air Vent Front Indicator Green.png Oxygen Tank is not stockpiling and can be drained.

0: O2 level < 25%
1: 25% <= O2 level < 50%
2: 50% <= O2 level < 75%
3: O2 level > 75%
4: Tank full.

Air Vent Front Indicator Blue.png Air Vent Front Indicator Blue.png Air Vent Front Indicator Blue.png Air Vent Front Indicator Blue.png Oxygen Tank is set to Stockpile. The tank will not release any oxygen and will drain other tanks that are not stockpiling.

0: O2 level < 25%
1: 25% <= O2 level < 50%
2: 50% <= O2 level < 75%
3: O2 level > 75%
4: Tank full.

Air Vent Front Indicator Red.png Air Vent Front Indicator Red.png Air Vent Front Indicator Red.png Air Vent Front Indicator Red.png Oxygen Tank deactivated or unpowered.

Media

Tips

  • It's helpful to keep one oxygen tank have its conveyor set to off, so that you can have one always ready. Just be sure to turn off your Oxygen Generator when you flip it back on.

Known Issues

  • Unlike cargo containers the actual cargo of the oxygen tank does not in anyway influence it's mass. Therefore the large block tank will ALWAYS have a mass of 3.1 tons whether its completely full of oxygen or not.

See also


Programming

Programming in the program block.

Interface name: IMyOxygenTank

Update History

Update 01.074
  • Oxygen Tank block introduced