! Reactor !! Small Ship !! Large Ship
 
! Reactor !! Small Ship !! Large Ship
 
|-
 
|-
| Small Reactor || 400 kW || 56 MW
+
| Small Reactor || 0.1 MW || 5 MW
 
|-
 
|-
| Large Reactor || 108 MW || 1512 MW
+
| Large Reactor || 3.5 MW || 100 MW
 
|-
 
|-
 
| Solar Panel  || 1.5* kW || 6* kW
 
| Solar Panel  || 1.5* kW || 6* kW
Line 25: Line 25:
 
! Ship !! Thrust !! Minimum Power !! Maximum Power !! Automatic Stabilizing
 
! Ship !! Thrust !! Minimum Power !! Maximum Power !! Automatic Stabilizing
 
|-
 
|-
| Small || Small || 0.0001 MW || 1.68 MW || 2.52 MW
+
| Small || Small || 0.0002 MW || 0.0336 MW || 0.0504 MW
 
|-
 
|-
| Small || Large || 0.0001 MW || 20 MW || 30 MW
+
| Small || Large || 0.0002 MW || 0.4 MW || 0.6 MW
 
|-
 
|-
| Large || Small || 0.0001 MW || 28 MW || 42 MW
+
| Large || Small || 0.0002 MW || 0.56 MW || 0.84 MW
 
|-
 
|-
| Large || Large || 0.0001 MW || 336 MW || 504 MW
+
| Large || Large || 0.0002 MW || 6.72 MW || 10.08 MW
 
|}
 
|}
  
Line 49: Line 49:
 
! Component !! Small Ship !! Large Ship
 
! Component !! Small Ship !! Large Ship
 
|-
 
|-
| Gravity Generator || N/A || **14 W - 567.13 kW
+
| Gravity Generator || N/A || **14 W - 0.56713 MW
 +
|-
 +
| Artificial Mass || 0.025 MW || 0.6 MW
 
|-
 
|-
 
| Interior Light || N/A || 0.0004 MW
 
| Interior Light || N/A || 0.0004 MW
Line 83: Line 85:
 
Not sure if the drill requires power while in standby.
 
Not sure if the drill requires power while in standby.
  
(Ver: 01.018.021)
+
(Ver: 01.035)
  
 
Notes: <br>
 
Notes: <br>

Revision as of 22:25, 19 June 2014


Electricity is a system and resource in Space Engineers that is used to power most devices. It is created using a large or small Reactor, or by using a Solar Panel. Any device that has a direct block connection to a reactor will be powered by a reactor; that is, if a reactor is on a ship, all devices attached to that ship should receive power granted there is enough power to receive. At this point in game development, Rotor blocks do not conduct electricity through themselves to other blocks, although they do consume it in order to function.

Reactors are powered by uranium ingots. 1L uranium ingots produces 68.76 MWs or 0.0191 MWh of energy.

The maximum amount a reactor can power:

Reactor Small Ship Large Ship
Small Reactor 0.1 MW 5 MW
Large Reactor 3.5 MW 100 MW
Solar Panel 1.5* kW 6* kW

( *Solar Panels have a maximum output depending on their angle to the sun and the amount of actually lit surface. Given values are the max achievable output with perfect conditions.)

Thrusts being used by the ship's inertia dampening will use 1.5x the maximum power.
Thrust power usage:

Ship Thrust Minimum Power Maximum Power Automatic Stabilizing
Small Small 0.0002 MW 0.0336 MW 0.0504 MW
Small Large 0.0002 MW 0.4 MW 0.6 MW
Large Small 0.0002 MW 0.56 MW 0.84 MW
Large Large 0.0002 MW 6.72 MW 10.08 MW

Refinery and assembler power usage (Individual Usage):

Mode Power Usage
Standby 0.001 MW
Operational 0.560 MW

Other component power usages:

Component Small Ship Large Ship
Gravity Generator N/A **14 W - 0.56713 MW
Artificial Mass 0.025 MW 0.6 MW
Interior Light N/A 0.0004 MW
Medical Room N/A  ? MW
Door N/A  ? MW
Gyroscope 0.00003 MW 0.0015 MW
Reflector Light 0.012 MW 0.0112 MW
Beacon 0.1 MW 0.1008 MW
Antenna  ? MW 0.1008 MW
Ore Detector  ? MW  ? MW
Conveyor  ? MW  ? MW
Drill .01 MW N/A
Gatling/Missile Turret N/A 0.1008 MW
Interior Turret N/A 0.1008 MW

(Ver: 01.013.008)

Notes:
Anything labeled "? MW" did not have power usage listed in the CubeBlocks.sbc file.
Noticed that lights, beacons, and antenna have power usage costs. However, have not thoroughly tested them.
Doors and reflector lights are off by default. All reflector lights are simultaneously turned on or off when using the toggle lights key.
Not sure if the drill requires power while in standby.

(Ver: 01.035)

Notes:
'**With the addition of gravity field properties, power cost of Gravity Generator is directly proportional to the field size and strength magnitude

  • novice test, drill uses 2.5% of 4 MW with a small reactor, whenever equipped, regardless of if it is active or not. Hence the value of .01 MW.