Air Vent

From Space Engineers Wiki
Revision as of 19:10, 22 July 2015 by Sapphire (talk | contribs) (Tips)
Jump to: navigation, search


Air Vent Icon.png
Large Ship Icon.png
Large Ship / Station
Air Vent
 
Components
Required

 

 
 
 
Mass (kg):
0
 
Integrity:
0
 
Build time (seconds):
50
 
Active power consumption (MW):
0.33
 
Idle Power Consumption (MW):
0.001
 
Dimensions (W x H x D):
1 x 1 x 1




Overview

This block was introduced in V1.074.
It's part of the games Oxygen system. An air vent must be connected to a source of oxygen in order to distribute breathable O2 to the room. Valid sources are for example an Oxygen Generator or an Oxygen Tank.

Usage

The air vent has to be connected to those blocks either directly by it's conveyor port on the back, or by connecting it to an existing Conveyor Network where at least one oxygen source block is present. (see above)

Air vent state indicator

On the front of the air vent are 4 indicators that show the current status of the vent and also deliver some information about the room the vent is installed in.

Game version: 1.078.009

Air Vent Front Indicator Green.png Air Vent Front Indicator Green.png Air Vent Front Indicator Green.png Air vent is pressurizing the room.
The number of indicators shows the current room pressure.
1: O2 level < 25%, 2: 25% <= O2 level < 50%, 3: 50% <= O2 level < 75%, 4: O2 level > 75%
Air Vent Front Indicator Blue.png Air Vent Front Indicator Blue.png Air vent set to "Depressurize". It draws O2 fromt he room until it's empty.
The number of indicators shows the remaining room pressure.
4: O2 level > 75%, 3: 50% <= O2 level < 75%, 2: 25% <= O2 level < 50%, 1: O2 level < 25%
Air Vent Front Indicator Yellow.png Room is not sealed against the open space. Air vent can't pressurize it.
Air Vent Front Indicator Red.png Air Vent Front Indicator Red.png Air Vent Front Indicator Red.png Air Vent Front Indicator Red.png Air vent deactivated


Oxygen ventilation capacities

Game version: 1.078.009

Input rate 300 O2/s Applicable when "Depressurize" option is selected
Output rate 300 O2/s Applicable when "Depressurize" option is not selected

Media

Tips

  • You can pressurize a room without it being connected to the conveyors to the oxygen generator. Simply connect a vent directly from the pressurized room to another vent in the non-pressurized one. Set the vent in the pressurized room to depressurize. The oxygen will be pulled from that room to the empty one.

Known Issues

Related Items

Programming

Update History

Update 01.074
  • Air vent block introduced