Difference between revisions of "Power Efficiency Upgrade Module"
Tofdesbois (talk | contribs) m (→Usage) |
Jagodragon (talk | contribs) (→Usage) |
||
Line 16: | Line 16: | ||
{|class="wikitable" style="text-align: center;" | {|class="wikitable" style="text-align: center;" | ||
|- | |- | ||
− | !No. of Modules | + | !No. of Modules || No. of Attachment Points || Total Power Efficiency|| Remaining Power Consumption || Power Consumption Difference to 1 less Module || Max Power Consumption For an Assembler [kW] |
|- | |- | ||
! 0 | ! 0 | ||
− | | 100% || 100%|| -|| 560.00 | + | | 0 || 100% || 100%|| -|| 560.00 |
|- | |- | ||
! 1 | ! 1 | ||
− | | 150% || 66.67% || - | + | | 1 || 122% || 81.77% || -18.23% || 457.95 |
+ | |- | ||
+ | ! 1 | ||
+ | | 2 || 150% || 66.67% || -15.1% || 374.49 | ||
+ | |- | ||
+ | ! 2 | ||
+ | | 3 || 183% || 54.69% || -11.98% || 306.25 | ||
|- | |- | ||
! 2 | ! 2 | ||
− | | 224% || 44.93% || -21.82% || 250.44 | + | | 4 || 224% || 44.93% || -21.82% || 250.44 |
+ | |- | ||
+ | ! 3 | ||
+ | | 5 ||273% || 36.57% || -8.36% || 204.80 | ||
|- | |- | ||
! 3 | ! 3 | ||
− | | 334% || 29.94% || - | + | | 6 ||334% || 29.94% || -6.63% || 167.48 |
+ | |- | ||
+ | ! 4 | ||
+ | | 7 ||409% || 24.46% || -5.48%|| 136.96 | ||
|- | |- | ||
! 4 | ! 4 | ||
− | | 500% || 20% || - | + | | 8 ||500% || 20% || -4.46% || 112.00 |
|} | |} | ||
Revision as of 22:33, 8 June 2023
2,996,000,000 mg
2.996 t
Contents
Overview
The Power Efficiency Module is a 2×1×1 block that can be placed on an Assembler or a Refinery to decrease power consumption.
Usage
This module, just like the Yield Module and the Speed Module, has 2 attachment points that look like small squares on the flat side of the block. These attachment points can be placed against the attachment points found on the backs of refineries or all sides of assemblers to increase the Power Efficiency of the refinery or assembler by +50% per attachment point. As both kinds of production blocks have 8 total attachment points, the maximum Power Efficiency for those blocks is 500% (100% for a refinery or assembler without any modules), which brings down power consumption to only 20% its original value.
These modules only affect the active power consumption (while the production block is working); it does not affect the minimum power consumption of the machine when idle.
Formula:
Total Power Efficiency = 1.2228445 ^ Attachment points connected to upgrade module, each module provides 2.
No. of Modules | No. of Attachment Points | Total Power Efficiency | Remaining Power Consumption | Power Consumption Difference to 1 less Module | Max Power Consumption For an Assembler [kW] |
---|---|---|---|---|---|
0 | 0 | 100% | 100% | - | 560.00 |
1 | 1 | 122% | 81.77% | -18.23% | 457.95 |
1 | 2 | 150% | 66.67% | -15.1% | 374.49 |
2 | 3 | 183% | 54.69% | -11.98% | 306.25 |
2 | 4 | 224% | 44.93% | -21.82% | 250.44 |
3 | 5 | 273% | 36.57% | -8.36% | 204.80 |
3 | 6 | 334% | 29.94% | -6.63% | 167.48 |
4 | 7 | 409% | 24.46% | -5.48% | 136.96 |
4 | 8 | 500% | 20% | -4.46% | 112.00 |
Media
Tips
- To maximize power efficiency it would take 16 Motors, 80 Power Cells, 80 Small Steel Tubes, 160 Construction Components, and 400 Steel Plates just to get that extra 500% power efficiency.