Difference between revisions of "Air Vent/zh"
From Space Engineers Wiki
(→通风口的状态标识) |
(→通风口的状态标识) |
||
Line 67: | Line 67: | ||
{| class="wikitable" | {| class="wikitable" | ||
|- | |- | ||
− | |[[File:Air_Vent_Front_Indicator_Green.png]] [[File:Air_Vent_Front_Indicator_Green.png]] [[File:Air_Vent_Front_Indicator_Green.png]] [[File:Air_Vent_Front_Indicator_Green.png]]||房间正被通风口加压<br /> | + | |[[File:Air_Vent_Front_Indicator_Green.png]] [[File:Air_Vent_Front_Indicator_Green.png]] [[File:Air_Vent_Front_Indicator_Green.png]] [[File:Air_Vent_Front_Indicator_Green.png]]||房间正被通风口加压<br />指标显示的格數為当前室内的压力。<br />'''1:''' O2 level < 25%, (氧氣含量低於25%)<br />'''2:''' 25% <= O2 level < 50%, (氧氣含量介乎25%至50%之間) <br />'''3:''' 50% <= O2 level < 75%, (氧氣含量介乎50%至75%之間) <br />'''4:''' O2 level > 75%(氧氣含量高於75%) <br /> |
|- | |- | ||
− | |[[File:Air_Vent_Front_Indicator_Blue.png]] [[File:Air_Vent_Front_Indicator_Blue.png]]|| | + | |[[File:Air_Vent_Front_Indicator_Blue.png]] [[File:Air_Vent_Front_Indicator_Blue.png]]||房间正被通风口減压, 它會抽取氧氣直到房間真空<br />The number of indicators shows the remaining room pressure.<br />'''4:''' O2 level > 75%, '''3:''' 50% <= O2 level < 75%, '''2:''' 25% <= O2 level < 50%, '''1:''' O2 level < 25% |
|- | |- | ||
|[[File:Air_Vent_Front_Indicator_Yellow.png]]||Room is not sealed against the open space. Air vent can't pressurize it. | |[[File:Air_Vent_Front_Indicator_Yellow.png]]||Room is not sealed against the open space. Air vent can't pressurize it. |
Revision as of 04:14, 12 April 2016
注意 |
---|
过期的信息 |
Contents
概述
此块是在V1.074推出
这是游戏中的氧气系统的一部分。通气孔必须连接到氧气源以釋放氧气到房间。有效的氧气来源,可以是一个氧气產生器或氧气罐。
用途
The air vent has to be connected to those blocks either directly by its conveyor port on the back, or by connecting it to an existing Conveyor Network where at least one oxygen source block is present. (see above)
通风口的状态标识
关于通气口上的4个指示器,用于显示排气阀的当前状态,并提供关于通风口被安装在房间的一些信息。
Game version: 1.105
Trigger other blocks
Air vents can trigger other blocks with the help of two configurations. The left action is triggered when the air vent detects 100% oxygen, the right action is triggered when the oxygen level drops to 0%, for example after the air vent was set to "Depressurize" or when the pressurized room is breached.
Oxygen ventilation capacities
Game version: 1.078.009
Input rate | 300 O2/s | Applicable when "Depressurize" option is selected |
Output rate | 300 O2/s | Applicable when "Depressurize" option is not selected |
Media
Tips
- You can pressurize a room without it being connected to the conveyors to the oxygen generator. Simply connect a vent directly from the pressurized room to another vent in the non-pressurized one. Set the vent in the pressurized room to depressurize. The oxygen will be pulled from that room to the empty one.
- Despite Small block Air Vents being available for small ships, small blocks cannot be used to make air tight rooms. Therefore its not possible to pressurize the cabin or internal parts of a small ship even if completely enclosed with normally airtight blocks such as small armor.
Known Issues
Related Items
Programming
Update History
Update 01.092 |
|
Update 01.074 |
|