Difference between revisions of "Safe Zone"
From Space Engineers Wiki
Vox Serico (talk | contribs) m (category) |
Vox Serico (talk | contribs) (Added power consumption formulas) |
||
Line 4: | Line 4: | ||
|Integrity | |Integrity | ||
|BuildTimeSeconds | |BuildTimeSeconds | ||
− | |MaxSafeZonePowerDrainkW | + | |MaxSafeZonePowerDrainkW#MW |
|MaxSafeZoneRadius | |MaxSafeZoneRadius | ||
− | |MinSafeZonePowerDrainkW | + | |MinSafeZonePowerDrainkW#MW |
|MinSafeZoneRadius | |MinSafeZoneRadius | ||
|SafeZoneActivationTimeS | |SafeZoneActivationTimeS | ||
Line 14: | Line 14: | ||
|IsAirTight | |IsAirTight | ||
|PCU | |PCU | ||
− | }} | + | }}<!-- |
− | {{CategorizeComponents|Mod:Vanilla/CubeBlock/SafeZoneBlock}} | + | -->{{CategorizeComponents|Mod:Vanilla/CubeBlock/SafeZoneBlock}}<!-- |
− | {{stub}} | + | -->{{stub}} |
+ | Impenetrable shield for large-grid stations. Costs [[Zone Chip]]s to run. | ||
+ | |||
+ | == Power Consumption == | ||
+ | {{#vardefine:minSafeZoneRadius|{{#show:Mod:Vanilla/CubeBlock/SafeZoneBlock|?MinSafeZoneRadius#-n}}}} | ||
+ | {{#vardefine:maxSafeZoneRadius|{{#show:Mod:Vanilla/CubeBlock/SafeZoneBlock|?MaxSafeZoneRadius#-n}}}} | ||
+ | {{#vardefine:minSafeZonePowerDrainMW|{{#expr:{{#show:Mod:Vanilla/CubeBlock/SafeZoneBlock|?MinSafeZonePowerDrainkW#-n}}/1000}}}} | ||
+ | {{#vardefine:maxSafeZonePowerDrainMW|{{#expr:{{#show:Mod:Vanilla/CubeBlock/SafeZoneBlock|?MaxSafeZonePowerDrainkW#-n}}/1000}}}} | ||
+ | {{#vardefine:radiusRange|{{#expr:{{#var:maxSafeZoneRadius}} - {{#var:minSafeZoneRadius}}}}}} | ||
+ | {{#vardefine:powerDrainRange|{{#expr:{{#var:maxSafeZonePowerDrainMW}} - {{#var:minSafeZonePowerDrainMW}}}}}} | ||
+ | {{#vardefine:boxRange|{{#expr:({{#var:maxSafeZoneRadius}}*2-{{#var:minSafeZoneRadius}})}}}} | ||
+ | |||
+ | The {{PAGENAME}} requires between {{#var:minSafeZonePowerDrainMW}} and {{#var:maxSafeZonePowerDrainMW}} MW while active, depending on the size of the zone. It requires only 1 W when inactive. | ||
+ | |||
+ | === Sphere-shape === | ||
− | + | Power drain in megawatts = | |
+ | (Radius − {{#var:minSafeZoneRadius}}) ÷ {{#var:radiusRange}} × {{#var:powerDrainRange}} + {{#var:minSafeZonePowerDrainMW}} | ||
+ | |||
+ | === Box-shape === | ||
+ | Power drain in megawatts = | ||
+ | ((SizeX − {{#var:minSafeZoneRadius}}) ÷ {{#var:boxRange}} ÷ 3 + | ||
+ | (SizeY − {{#var:minSafeZoneRadius}}) ÷ {{#var:boxRange}} ÷ 3 + | ||
+ | (SizeZ − {{#var:minSafeZoneRadius}}) ÷ {{#var:boxRange}} ÷ 3) × {{#var:powerDrainRange}} + {{#var:minSafeZonePowerDrainMW}} |
Latest revision as of 11:17, 27 January 2021
Dimensions (W,H,L)2,2,3
Mass26,545.25 kg
26,545,250 g
26,545,250,000 mg
26.545 t
26,545,250,000 mg
26.545 t
Integrity95,925
Build time40 s
Max Safe-Zone Power Drain300 MW
300,000 kW
300,000,000 W
300,000,000 W
Max Safe-Zone Radius500 m
Min Safe-Zone Power Drain5 MW
5,000 kW
5,000,000 W
5,000,000 W
Min Safe-Zone Radius10 m
Safe-Zone Activation Time120 s
2 min
Safe-Zone Upkeep1 ZoneChip(s)
Safe-Zone Upkeep Time60 min
3,600 s
Inventory Volume5 L
0.005 m³
0.5 hL
0.5 hL
Is AirtightPartially
PCU Cost50
BrowseLast edit: 2020-05-15
Impenetrable shield for large-grid stations. Costs Zone Chips to run.
Power Consumption
The Safe Zone requires between 5 and 300 MW while active, depending on the size of the zone. It requires only 1 W when inactive.
Sphere-shape
Power drain in megawatts = (Radius − 10) ÷ 490 × 295 + 5
Box-shape
Power drain in megawatts = ((SizeX − 10) ÷ 990 ÷ 3 + (SizeY − 10) ÷ 990 ÷ 3 + (SizeZ − 10) ÷ 990 ÷ 3) × 295 + 5